HPLC Pumps / Precision Pumps
-
Pressure up tp 9000 psi(62 MPa),Flow rate up to10 mL / min
-
Isocratic, Binary and Quaternary Pumps
-
Dual pumps with precise feedback control design improve pressure stability
-
Quaternary system with innovative gradient proportional valve, gradient accuracy less than 1%
-
Pressure up tp 9000 psi(62 MPa),Flow rate up to10 mL / min
Isocratic, Binary and Quaternary Pumps
Dual pumps with precise feedback control design improve pressure stability
Quaternary system with innovative gradient proportional valve, gradient accuracy less than 1%

The core of the liquid chromatography system is a high-pressure pump, which is used to transport the mobile phase solvent and the sample to be measured into the chromatographic column. Rittun LC infusion pumps provide the pressure needed to overcome column resistance while providing stable pressure (pulsation-free) at precisely controlled flow rates.
Rittun liquid chromatography infusion pump combines a control algorithm and a dual-piston constant flow pump design to achieve precise flow and pressure control. The dual piston pump design integrates a primary pump to transfer fluid and a secondary pump working in series to control pulsation and flow rate. Rittun LC infusion pumps include overpressure and leak alarms to increase safety and pump reliability.
Isocratic Pump
· A two-stage pump for isocratic elution
Binary Pump
· Two two-stage pumps mix two mobile phases of different polarity in any ratio to produce isocratic or gradient elution.
Quaternary Pump
· Four-stage solenoid distribution valve can control the flow of 4 solvents with different polarities at low pressure
· A two-stage high-pressure pump delivers the combined liquid to the column.
· Use a quaternary valve in combination with a high-pressure pump to produce isocratic or gradient elution
|
Data |
Pressure |
9000 psi @ 0.000 mL/min – 2.000 mL/min 6000 psi @ 2.001 mL/min – 5.000 mL/min 3000 psi @ 5.001 mL/min – 10.00 mL/min |
Flow Rate |
0.001 mL/min – 10.00 mL/min |
Flow Accuracy |
± 0.5% @ 1 mL/min, H2O |
Flow RSD |
0.1% @ 1 mL/min, H2O |
Gradient Accuracy (L-3220 & L-3245) |
±1 % |
Gradient RSD (L-3220 & L-3245) |
0.2% |
In-Line Degasser (L-3245 Only) |
4-Channel (480 µL/Channel) |
|
|
|
|
|
Data |
Weight |
L-3321 17 kg (37.5 lbs) L-3220 22 kg (48.5 lbs) L-3245 17 kg (37.5 lbs) |
Size (LxWxH) |
464 x 370 x 143 mm 18.3 x 14.6 x 5.7 inches |
Voltage |
110 VAC rms – 240 VAC rms |
Frequency |
50 Hz – 60 Hz |
Power |
60 W max |
Operation Temp |
15 ° C – 35 ° C 59 ° F – 95 ° F |
Operation Humidity |
20% RH – 80% RH |
Model
Description
L3210
Isocratic Pump
L3220
Binary Pump
L3245
Quaternary Pump with degasser